Spectrophotometers
Hach DR6000™ UV VIS Spectrophotometer with RFID Technology (DR6000 with RFID)
The DR6000™ is the industry’s most advanced laboratory spectrophotometer for water testing. It offers high-speed wavelength scanning across the UV and Visible Spectrum, and comes with over 250 pre-programmed methods including the most common water and environmental testing methods used today. With optional accessories allowing for high-volume testing via a carousel sample changer, and increased accuracy with a sample delivery system that eliminates optical difference errors, this instrument ensures you are ready to handle your wide-ranging water testing needs.Combining the DR6000 with Hach’s patented TNTplus™ test kits, you gain additional accuracy with guided step-by-step testing procedures, while making scratched, flawed or dirty glassware a non-issue due to averaging 10 readings and discarding outliers. The spectrophotometers also utilizes RFID technology, allowing it to let you know automatically if your TNTplus test kits have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries.Partnering all of these features with an integrated quality assurance software package allows for scheduling, documenting and interpreting your needed quality measurements.Your water and environmental testing needs, all in one spectrophotometer.*RFID currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands. Customers in other countries should order LPV441.99.00002.
Data Logger:5000 data points (result, date, time, sample-ID, user-ID)Display:TFT 7 inch WVGA color touchEnclosure Rating:IP20 with closed lidInterfaces:USB type A (2), USB type B, Ethernet, RFID moduleManual Languages:en, es, fr, ja, ko, pt, zhOperating Conditions:10 - 40 °C, max. 80% relative humidity (non-condensing)Operating Mode:Transmittance (%), absorbance and concentration (wavelength, time)Optical System:Reference beam, spectralPhotometric Accuracy: # 5 mAbs @ 0.0 - 0.5 Abs
Optional 100 mm rectangular cell with additional adapter
Scanning Speed: 900 nm/min (in 1 nm steps)
Source Lamp: Tungsten (visible range), deuterium (UV range)
Specific Technology: RFID for easy method update, sample ID and Certificate of Analysis
Spectral Bandwidth: 2 nm
Storage Conditions: -25 to 60 °C / max. 80% relative humidity (non-condensing)
Stray Light: KI-solution at 220 nm < 3.3 Abs/ < 0.05%
User Interface Languages: bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr
User Programs: 200
Warranty: 12 months
Wavelength Accuracy: ± 1 nm
Wavelength Range: 190 - 1100 nm
Wavelength Reproducibility: < 0.1 nm
Wavelength Resolution: 0.1 nm
Wavelength Selection: Automatic, based on method selection
Weight: 11 kg
Key features
- Your Water Testing Needs, All in One Spectrophotometer
- Accessories for High Volume and High Accuracy Testing Needs
- Advanced Quality Assurance at Your Fingertips
- Guided Procedures and Elimination of False Readings
- Automatically Avoids Errors
Data Logger:5000 data points (result, date, time, sample-ID, user-ID)Display:TFT 7 inch WVGA color touchEnclosure Rating:IP20 with closed lidInterfaces:USB type A (2), USB type B, Ethernet, RFID moduleManual Languages:en, es, fr, ja, ko, pt, zhOperating Conditions:10 - 40 °C, max. 80% relative humidity (non-condensing)Operating Mode:Transmittance (%), absorbance and concentration (wavelength, time)Optical System:Reference beam, spectralPhotometric Accuracy: # 5 mAbs @ 0.0 - 0.5 Abs
- <1% @ 0.5 - 2.0 Abs @ 546 nmPhotometric Linearity: # 0.005 - 2 Abs
- ≤ 0.01 at > 2 Abs with neutral glass at 546 nmPhotometric Measuring Range:± 3 AbsPower Requirements:100 - 240 V; 50/60 HzPreprogrammed Methods:> 240Region:USSample Cell Compatibility:Rectangular:
- 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch
Optional 100 mm rectangular cell with additional adapter
Scanning Speed: 900 nm/min (in 1 nm steps)
Source Lamp: Tungsten (visible range), deuterium (UV range)
Specific Technology: RFID for easy method update, sample ID and Certificate of Analysis
Spectral Bandwidth: 2 nm
Storage Conditions: -25 to 60 °C / max. 80% relative humidity (non-condensing)
Stray Light: KI-solution at 220 nm < 3.3 Abs/ < 0.05%
User Interface Languages: bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr
User Programs: 200
Warranty: 12 months
Wavelength Accuracy: ± 1 nm
Wavelength Range: 190 - 1100 nm
Wavelength Reproducibility: < 0.1 nm
Wavelength Resolution: 0.1 nm
Wavelength Selection: Automatic, based on method selection
Weight: 11 kg
Key features
- 1x DR6000 UV VIS Spectrophotometer
- 1x Power Cord (US, EU) 1x Universal-Adapter
- 1x Dust Cover
- Matched pair of 1 inch glass sample cells
- Printed multilingual basic user manual (en, fr, es, pt, zh, jp, ko)
Hach DR6000™ UV VIS Spectrophotometer without RFID (DR6000 without RFID)
The DR6000™ is the industry’s most advanced lab spectrophotometer. It offers high speed wavelength scanning across the UV and Visible Spectrum, and comes with over 250 pre-programmed methods which include the most common testing methods used today. With optional accessories allowing for high volume testing via a carousel sample changer, and increased accuracy with a sample delivery system which eliminates optical difference errors, this instrument ensures you are ready to handle your wide-ranging water testing needs.Combining the DR6000 with Hach’s patented TNTplus™ reagent vials, you gain additional accuracy with guided step-by-step testing procedures, while making scratched, flawed or dirty glassware a non-issue due to 10 reading averages and the discarding of outliers. The instrument also utilizes RFID technology, allowing it to automatically let you know if your TNTplus reagents have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries.Partnering all of these features with an integrated QA software package allows for scheduling, documenting and interpreting your needed quality measurements.This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.Your water testing needs, all in one spectrophotometer.*In the US, Puerto Rico, Australia, New Zealand, and Colombia the instrument is available with RFID. Customers in those countries should order LPV441.99.00012.
Cuvette Compatibility 2: 1 inch rectangular and round cell
Cuvette Compatibility 3: Optional 100 mm rectangular cell with additional adapter
Data Logger: 5000 data points (result, date, time, sample-ID, user-ID)
Display: TFT 7" WVGA color touch
Enclosure Rating: IP20 with closed lid
Mains Connection 2: 50 - 60 Hz
Manual Languages: en, es, fr, ja, ko, pt, zh
Operating Conditions: 10 - 40 °C, max. 80% relative humidity (non-condensing)
Optical System: Reference beam, spectral
Photometric Accuracy: 5 mAbs @ 0.0 - 0.5 Abs
Photometric Linearity: 0.5 % - 2 Abs
Photometric Linearity 2: 1 % at > 2 Abs with nutral glass at 546 nm
Photometric Measuring Range: ± Abs
Power Requirements: 100 - 240 V
Preprogrammed Methods: > 250
Region: US
Sample Cell Compatibility: 10, 20, 30, 50 mm rectangular cell
Scanning Speed: 900 nm/min (in 1 nm steps)
Source Lamp: Tungsten (visible range) , deuterium (UV range)
Specific Technology: RFID not applicable with this model
Spectral Bandwidth: 2 nm
Storage Conditions: -25 °C to 60 °C max. 80% relative humidity (non-condensing)
Stray light: < 0.05 %
Stray Light: KI-solution at 220 nm < 3.3 Abs
User Interface Languages: bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr
User Programs: 200
Warranty: 12 months
Wavelength Accuracy: ± 1 nm
Wavelength Range: 190 - 1100 nm
Wavelength Reproducibility: < 0.1 nm
Wavelength Resolution: 0.1 nm
Wavelength Selection: Automatic
Weight: 11 kg
- Your Water Testing Needs, All in One Spectrophotometer
- Accessories for High Volume and High Accuracy Testing Needs
- Advanced Quality Assurance at Your Fingertips
- Guided Procedures and Elimination of False Readings
- Large Color Touch Screen Interface
Cuvette Compatibility 2: 1 inch rectangular and round cell
Cuvette Compatibility 3: Optional 100 mm rectangular cell with additional adapter
Data Logger: 5000 data points (result, date, time, sample-ID, user-ID)
Display: TFT 7" WVGA color touch
Enclosure Rating: IP20 with closed lid
Mains Connection 2: 50 - 60 Hz
Manual Languages: en, es, fr, ja, ko, pt, zh
Operating Conditions: 10 - 40 °C, max. 80% relative humidity (non-condensing)
Optical System: Reference beam, spectral
Photometric Accuracy: 5 mAbs @ 0.0 - 0.5 Abs
Photometric Linearity: 0.5 % - 2 Abs
Photometric Linearity 2: 1 % at > 2 Abs with nutral glass at 546 nm
Photometric Measuring Range: ± Abs
Power Requirements: 100 - 240 V
Preprogrammed Methods: > 250
Region: US
Sample Cell Compatibility: 10, 20, 30, 50 mm rectangular cell
Scanning Speed: 900 nm/min (in 1 nm steps)
Source Lamp: Tungsten (visible range) , deuterium (UV range)
Specific Technology: RFID not applicable with this model
Spectral Bandwidth: 2 nm
Storage Conditions: -25 °C to 60 °C max. 80% relative humidity (non-condensing)
Stray light: < 0.05 %
Stray Light: KI-solution at 220 nm < 3.3 Abs
User Interface Languages: bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr
User Programs: 200
Warranty: 12 months
Wavelength Accuracy: ± 1 nm
Wavelength Range: 190 - 1100 nm
Wavelength Reproducibility: < 0.1 nm
Wavelength Resolution: 0.1 nm
Wavelength Selection: Automatic
Weight: 11 kg
Hach DR1900 Portable Spectrophotometer (DR1900)
The DR1900 is perfect for use in the field because it is the lightest and most compact portable spectrophotometer. It also can perform that largest number of tests of any portable instrument. Underneath the rugged exterior, the DR1900 has the largest number--over 220--of the most commonly tested preprogrammed methods already built in. You can also use the easy-to-use interface to create your own methods. Also, it is flexible because you can use the widest range of vial sizes of any other spectrophotometer.
Portability - Easy to hold, and operate, the compact DR1900 is a valuable tool for your field technicians. This is lightest and smallest spec on the market.
Accuracy - Tests are performed with a wavelength range of 340 to 800 nm, which make this a field instrument you can use to find results typically only seen in laboratory instruments.
Ruggedness - The DR1900 is built for rugged conditions. Built as a hand-held spec the DR1900 has a large, clear screen and a simple user interface that makes testing easier than ever in even the most demanding conditions.
Upgrade from your DR2800 or order a new DR1900 today!
Please note: LCK cuvette test evaluation possible, but without barcode reading & 10 fold measurement feature.
Carry anywhere due to a compact design
Test what you need with hundreds of built-in methods
Ensure accuracy in the field
Make testing easier with a clear, easy-to-use interface
Test in demanding environments - water and dust-proof design
Key performance specifications
Battery life: 15 days (typical) @ 5 readings a day / 5 day week without backlight*
* Backlight usage will decrease battery life.
Battery requirements: 4 AA size batteries
Cuvette compatibility: 10 mm square / 1 inch square and
13 mm / 1 inch round
13 mm and 1 inch round 10 x 10 mm 1 inch square adapter for round vials and 10x10mm
Data storage: 500 measured values (Result, Date, Time, Sample ID, User ID acc. to GLP)
Detector: Silicon photodiode
Dimensions (H x W x D):98 mm x 178 mm x 267 mm
Display: Graphical display 240 x 160 pixel (LCD, b/w, backlit)
Enclosure waterproof rating: IP67
Environmental conditions: relative humidity:Max. 80 % relative humidity (non-condensing)
Environmental conditions: temperature:10 - 40 °C
Interface: USB type Mini IP67 (with optional Module)
Operating conditions: 10 - 40 °C, max. 80 % relative humidity (non-condensing)
Operating mode: Transmittance (%), Absorbance and Concentration
Optical system: Reference beam, spectral
Photometric accuracy: ± 0.003 Abs @ 0.0 - 0.5 Abs
Photometric linearity: < 0.5 % (0.5 - 2.0 Abs)
Photometric measuring range: 0 - 3 Abs (wavelength range 340 - 800 nm)
Power Module?: No
Power supply: # 110 - 240 V / 50/60 Hz (* optional Module required. May not be avaliable in all region)
4 x AA size Alkaline
4x NiMH rechargeable Battery*
Power supply*: # 110 - 240 V; 50/60 Hz
(* optional Module required. May not be available in all regions)
# 4x NiMH rechargeable Battery (* optional Module required. May not be avaliable in all region)
Pre-programmed methods:220 (Please note: LCK cuvette tests can be evaluated, but without 10-fold rotational measurement and barcode readers.)
Region: EU
Reproducibility: ± 0.005 Abs (0 - 1 A)
Source lamp: Xenon Flash
Storage conditions: -30 - 60 °C (-30 - 140 °F), max. 80 % relative humidity (non-condensing)
Stray light: < 0.5 %T at 340 nm with NaNO2
Temperature range: 0 - 50 °C
User interface: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
User programmes: 50
Warranty: 12 months
Wavelength accuracy: ± 2 nm (range 340 - 800nm)
Wavelength calibration: Automatic
Wavelength range: 340 - 800 nm
Wavelength selection: Automatic
Weight: 1.5 kg
Portability - Easy to hold, and operate, the compact DR1900 is a valuable tool for your field technicians. This is lightest and smallest spec on the market.
Accuracy - Tests are performed with a wavelength range of 340 to 800 nm, which make this a field instrument you can use to find results typically only seen in laboratory instruments.
Ruggedness - The DR1900 is built for rugged conditions. Built as a hand-held spec the DR1900 has a large, clear screen and a simple user interface that makes testing easier than ever in even the most demanding conditions.
Upgrade from your DR2800 or order a new DR1900 today!
Please note: LCK cuvette test evaluation possible, but without barcode reading & 10 fold measurement feature.
Carry anywhere due to a compact design
Test what you need with hundreds of built-in methods
Ensure accuracy in the field
Make testing easier with a clear, easy-to-use interface
Test in demanding environments - water and dust-proof design
Key performance specifications
Battery life: 15 days (typical) @ 5 readings a day / 5 day week without backlight*
* Backlight usage will decrease battery life.
Battery requirements: 4 AA size batteries
Cuvette compatibility: 10 mm square / 1 inch square and
13 mm / 1 inch round
13 mm and 1 inch round 10 x 10 mm 1 inch square adapter for round vials and 10x10mm
Data storage: 500 measured values (Result, Date, Time, Sample ID, User ID acc. to GLP)
Detector: Silicon photodiode
Dimensions (H x W x D):98 mm x 178 mm x 267 mm
Display: Graphical display 240 x 160 pixel (LCD, b/w, backlit)
Enclosure waterproof rating: IP67
Environmental conditions: relative humidity:Max. 80 % relative humidity (non-condensing)
Environmental conditions: temperature:10 - 40 °C
Interface: USB type Mini IP67 (with optional Module)
Operating conditions: 10 - 40 °C, max. 80 % relative humidity (non-condensing)
Operating mode: Transmittance (%), Absorbance and Concentration
Optical system: Reference beam, spectral
Photometric accuracy: ± 0.003 Abs @ 0.0 - 0.5 Abs
Photometric linearity: < 0.5 % (0.5 - 2.0 Abs)
Photometric measuring range: 0 - 3 Abs (wavelength range 340 - 800 nm)
Power Module?: No
Power supply: # 110 - 240 V / 50/60 Hz (* optional Module required. May not be avaliable in all region)
4 x AA size Alkaline
4x NiMH rechargeable Battery*
Power supply*: # 110 - 240 V; 50/60 Hz
(* optional Module required. May not be available in all regions)
# 4x NiMH rechargeable Battery (* optional Module required. May not be avaliable in all region)
Pre-programmed methods:220 (Please note: LCK cuvette tests can be evaluated, but without 10-fold rotational measurement and barcode readers.)
Region: EU
Reproducibility: ± 0.005 Abs (0 - 1 A)
Source lamp: Xenon Flash
Storage conditions: -30 - 60 °C (-30 - 140 °F), max. 80 % relative humidity (non-condensing)
Stray light: < 0.5 %T at 340 nm with NaNO2
Temperature range: 0 - 50 °C
User interface: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
User programmes: 50
Warranty: 12 months
Wavelength accuracy: ± 2 nm (range 340 - 800nm)
Wavelength calibration: Automatic
Wavelength range: 340 - 800 nm
Wavelength selection: Automatic
Weight: 1.5 kg
Hach DR3900 Laboratory Spectrophotometer for water analysis (DR3900)
laboratory water analysis. With your daily routine of water analysis in mind, the DR3900 spectrophotometer is optimized for safe processes and accurate results. Control-parameters like Ammonium, COD, Phosphate, Nitrate and many others are easy to perform. The handling of tests and spectrophotometer is well designed to avoid any errors in your water analysis.
Simple Preparation
TNTplus® vials use Dosicaps - freeze-dried reagents integrated into sealed cap - that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination.
The boxes and vials are color-coded for a fast and easy parameter and range recognition of exactly the test you need. Step-by-step illustrated test methods are printed on the box as a quick reference and can also be called up in the instrument menu.
Comprehensive Documentation
Measurement results are documented on the detailed level with timestamp, operator ID, absorbance reading, and calculated concentration. The 2D barcode delivers the lot number and expiry date, logged with every result. For your accreditation the certificate of analysis can be called up just by wiping the reagent box towards the RFID* sensor.
*RFID technology currently available in US, Canada, Puerto Rico, Australia, New Zealand, and Colombia only.
Fast execution
A 2D barcode on the TNTplus vial is automatically read by the Hach DR spectrophotometer to identify the appropriate method and take the measurement. The vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints. Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks.
Customizable
With the ability to store hundreds of user-determined methods, operators are able to tailor the DR3900 to meet the everyday needs of the plant. Being able to optimize and customize the method portfolio, combined with regular software updates and Claros™ connectivity, makes the DR3900 the ultimate solution to water quality lab needs.
Key performance specifications
Power Requirements: With external power supply
Power Requirements (Hz): 50/60 Hz
Power Requirements (Voltage): 110 - 240 V AC
Power Supply: Benchtop Power Supply
Preprogrammed Methods: > 240
Region: US
Sample Cell Compatibility: Rectangular : 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch
Scanning Speed: > 8 nm/S (in steps of 1 nm)
Source Lamp: Gas-filled Tungsten (visible)
Specific Technology: RFID for easy method update, sample ID and Certificate of Analysis
Spectral Bandwidth: 5 nm ± 1 nm
Standard accessories: None
Storage Conditions: -30 - 60 °C
Stray Light: < 0.1 % T at 340 nm with NaNO2
User Interface Languages: Bulgarian, Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Polish, Portuguese - Brasilian, Potuguese, Russian, Serbian, Slovakian, Slowenian, Spanish, Swedish, Turkish
User Programs: 100
Warranty: 12 months
Wavelength Accuracy: ± 1.5 nm (wavelength range 340 - 900 nm)
Wavelength Calibration: Automatic
Wavelength Range: 320 - 1100 nm
Wavelength Reproducibility: ± 0.1 nm
Wavelength Resolution: 1 nm
Wavelength Selection: Automatic, based on method selection
Weight: 4.2 kg
Key features
Simple Preparation
TNTplus® vials use Dosicaps - freeze-dried reagents integrated into sealed cap - that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination.
The boxes and vials are color-coded for a fast and easy parameter and range recognition of exactly the test you need. Step-by-step illustrated test methods are printed on the box as a quick reference and can also be called up in the instrument menu.
Comprehensive Documentation
Measurement results are documented on the detailed level with timestamp, operator ID, absorbance reading, and calculated concentration. The 2D barcode delivers the lot number and expiry date, logged with every result. For your accreditation the certificate of analysis can be called up just by wiping the reagent box towards the RFID* sensor.
*RFID technology currently available in US, Canada, Puerto Rico, Australia, New Zealand, and Colombia only.
Fast execution
A 2D barcode on the TNTplus vial is automatically read by the Hach DR spectrophotometer to identify the appropriate method and take the measurement. The vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints. Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks.
Customizable
With the ability to store hundreds of user-determined methods, operators are able to tailor the DR3900 to meet the everyday needs of the plant. Being able to optimize and customize the method portfolio, combined with regular software updates and Claros™ connectivity, makes the DR3900 the ultimate solution to water quality lab needs.
Key performance specifications
Power Requirements: With external power supply
Power Requirements (Hz): 50/60 Hz
Power Requirements (Voltage): 110 - 240 V AC
Power Supply: Benchtop Power Supply
Preprogrammed Methods: > 240
Region: US
Sample Cell Compatibility: Rectangular : 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch
Scanning Speed: > 8 nm/S (in steps of 1 nm)
Source Lamp: Gas-filled Tungsten (visible)
Specific Technology: RFID for easy method update, sample ID and Certificate of Analysis
Spectral Bandwidth: 5 nm ± 1 nm
Standard accessories: None
Storage Conditions: -30 - 60 °C
Stray Light: < 0.1 % T at 340 nm with NaNO2
User Interface Languages: Bulgarian, Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Polish, Portuguese - Brasilian, Potuguese, Russian, Serbian, Slovakian, Slowenian, Spanish, Swedish, Turkish
User Programs: 100
Warranty: 12 months
Wavelength Accuracy: ± 1.5 nm (wavelength range 340 - 900 nm)
Wavelength Calibration: Automatic
Wavelength Range: 320 - 1100 nm
Wavelength Reproducibility: ± 0.1 nm
Wavelength Resolution: 1 nm
Wavelength Selection: Automatic, based on method selection
Weight: 4.2 kg
Key features
- Simple Preparation with TNTplus® vials
- Store hundreds of user-determined methods
- Claros™ connectivity
- 1