The TDP0500 is a high voltage Differential Probe specifically designed for use with and direct connection to Tektronix oscilloscopes with either the TekVPI™ probe interface or TekProbe BNC. 500MHz probe with TekVPI interface. Easy to use - provides automatic units scaling and readout on the oscilloscope display. Easy access to scope-displayed probe menu for probe setup control and operating status information. Remote GPIB/USB probe control through the oscilloscope.
• Outstanding electrical performance
• Zeros out output offset
• Versatile DUT connectivity
• Robust design for reliability
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
• Attenuation: 5X / 50X
• Bandwidth: 500 MHz
• Input Impedance: 1 MΩ || ≤ 1 pF
• Maximum Voltage
o 50X: ± 42 V
o 5X: ± 4.2 V
• Selectable Bandwidth-limiting Filters
Applications
Test & Measurement, Power Management, Communications & Networking, Embedded Design & Development
Footnotes
Calibration services available for this product. Choose from a Standard Certificated Service or an internationally recognised UKAS accredited calibration. Visit our calibration page for more details.
Key performance specifications
Bandwidth (Probe only) 500 MHz
Attenuation 5x, 50x
Rise Time (Probe only) <700 ps
Differential Input Capacitance <1 pF
Differential Input Resistance 1 MΩ
CMRR >55 dB at 30 kHz
>50 dB at 1 MHz
>18 dB at 250 MHz (warranted at 50x attenuation)
Sensitivity/Noise Level 2 mV RMS (5x attenuation)
1 mV RMS (50x attenuation) referred to the probe output
10 mV RMS (5x attenuation)
50 mV RMS (50x attenuation) referred to the probe input
Differential Mode Input Voltage ±42 V (DC + pk AC); 30 V RMS
Common Mode Input Voltage ±35 V (DC + pk AC); 25 V RMS
Input Offset Range ±42 V (5x or 50x attenuation)
Max Input Voltage (Nondestruct) ±100 V (DC + pk AC)
Selectable Bandwidth Filter Limits 100 Hz, 10 kHz, 1 MHz, Full
DC Reject 0.4 Hz (5x)
4 Hz (50x)
Gain Accuracy at DC ±2%
Propagation Delay 6.5 ns
Scope Interface TekVPI™ Probe Interface
Tech Specs
Test Equipment General Attributes
Product Height 3.40 IN
Product Length 14.70 IN
Product Width 12.80 IN
Shipping Weight 2.80 LBS
Country of Origin United States
Shipping Height 3.40 IN
Shipping Length 14.70 IN
Shipping Width 12.80 IN
• Outstanding electrical performance
• Zeros out output offset
• Versatile DUT connectivity
• Robust design for reliability
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
• Attenuation: 5X / 50X
• Bandwidth: 500 MHz
• Input Impedance: 1 MΩ || ≤ 1 pF
• Maximum Voltage
o 50X: ± 42 V
o 5X: ± 4.2 V
• Selectable Bandwidth-limiting Filters
Applications
Test & Measurement, Power Management, Communications & Networking, Embedded Design & Development
Footnotes
Calibration services available for this product. Choose from a Standard Certificated Service or an internationally recognised UKAS accredited calibration. Visit our calibration page for more details.
Key performance specifications
Bandwidth (Probe only) 500 MHz
Attenuation 5x, 50x
Rise Time (Probe only) <700 ps
Differential Input Capacitance <1 pF
Differential Input Resistance 1 MΩ
CMRR >55 dB at 30 kHz
>50 dB at 1 MHz
>18 dB at 250 MHz (warranted at 50x attenuation)
Sensitivity/Noise Level 2 mV RMS (5x attenuation)
1 mV RMS (50x attenuation) referred to the probe output
10 mV RMS (5x attenuation)
50 mV RMS (50x attenuation) referred to the probe input
Differential Mode Input Voltage ±42 V (DC + pk AC); 30 V RMS
Common Mode Input Voltage ±35 V (DC + pk AC); 25 V RMS
Input Offset Range ±42 V (5x or 50x attenuation)
Max Input Voltage (Nondestruct) ±100 V (DC + pk AC)
Selectable Bandwidth Filter Limits 100 Hz, 10 kHz, 1 MHz, Full
DC Reject 0.4 Hz (5x)
4 Hz (50x)
Gain Accuracy at DC ±2%
Propagation Delay 6.5 ns
Scope Interface TekVPI™ Probe Interface
Tech Specs
Test Equipment General Attributes
Product Height 3.40 IN
Product Length 14.70 IN
Product Width 12.80 IN
Shipping Weight 2.80 LBS
Country of Origin United States
Shipping Height 3.40 IN
Shipping Length 14.70 IN
Shipping Width 12.80 IN
Write Review
-